Home    About Us   Products  Project Performance   News   Recrui Tment   Bulletin Board   Contact Us
 
   
 

Los coldwell high strength roof rock wool board

 

CSR PANEL

 

Constant temperature and humidity laboratory

 

Refrigeration equipment

 

Clean Room

 

Cold Storage

   
Home >> Products
 
 
Product Name:
产品信息:
First, the program outlined in the laboratory temperature and humidity
     Constant temperature and humidity laboratory is a laboratory, through some special equipment and technical means to comply with the indoor temperature and humidity in a humidity and testing requirements of the standard atmosphere. Constant temperature and humidity of the laboratory is the production test and control product quality and circulation of commodities in the field of quality infrastructure quality. Constant temperature and humidity are widely used in laboratory cotton, wool, chemical fiber, paper, packaging, tobacco manufacturers, as well as quality inspection,纤检other departments, in accordance with the relevant ISO and GB standards, textiles, textile raw materials, paper, paper products and cardboard boxes the quality of commodities such as physical inspection of the project must be carried out under standard atmospheric conditions. Textiles and textile raw materials in accordance with the test atmosphere and ISO139 standards GB6529, temperature 20 ± 2 ℃, relative humidity 65% ± 2%; paper, paper products and cardboard boxes of the standard categories of Commodity Inspection and the atmosphere in accordance with the ISO187 standard GB10739, temperature 23 ± 1 ℃, relative humidity 50% ± 2%. In addition to conventional laboratory temperature and humidity in the constant temperature and humidity, as well as other special low-temperature 5-18 ℃ high temperature ,30-80 ℃, relative humidity requirements of less than 40% RH humidity, relative humidity above 80% RH of humidity and other special Laboratory temperature and humidity requirements.


We can provide constant temperature and humidity of the laboratory:
Types of temperature and humidity in the application of industry
Conventional constant temperature and humidity laboratory 18-30 ℃, 45% -70% RH textile, paper, precision manufacturing
Constant temperature and humidity laboratory temperature 12-18 ℃, 45% -70% RH film preservation, such as drug research
Ultra-low temperature 5-12 ℃ constant temperature and humidity laboratory biological cultivation, storage library, etc.
Room temperature and humidity aging 30-80 ℃, 40% -95% of electronic products of high temperature or high temperature and humidity aging test

 
Part of industry standards for temperature and humidity detection:
Textile sub-plastic coating paper
Temperature 23 ± 1 ℃ 20 ± 1 ℃ 20 ± 1 ℃ 23 ± 2 ℃
Relative humidity of 50 ± 2% 65 ± 2% 50 ± 3% 50 ± 5%
Cycles of 15 ~ 30 / h 15 ~ 30 times / h 15 ~ 30 times / h 15 ~ 30 times / h
Air velocity ≤ 0.3m / s ≤ 0.25m / s ≤ 0.3m / s ≤ 0.3m / s
To add new wind ≥ 0.5m2 / person. At ≥ 0.5m2 / person. At ≥ 0.5m2 / person. At ≥ 0.5m2 / person. Sub -
Noise ≤ 55dB ≤ 55dB ≤ 55dB ≤ 55dB
The national standard GB10739 GB6529 GB/T2918 GB9278
International standard ISO187 ISO139 ISO291 ISO3270
 
 
 
Second, the design features of the program
      The overall planning of the laboratory, it is necessary to take into account the following requirements: a very wide scope, the need of construction, water, electricity, air conditioning, laboratory professionals and other users to participate in the planning.
• Design Objective: To create a laboratory equipment can ensure that its stable and reliable operation, extending its life, can meet user requirements and the physical and mental health staff in the workplace.
• design: taking full account of the professional relationship between the strict coordination, do good, do not leak, do not touch.
• specific design: the use of advanced technology at home and abroad, selected not only advanced, cost-effective and reasonable environmental protection equipment and materials, integration of the design concept of human nature.
&, Constant temperature and humidity design planning elements Laboratory
1. 2 temperature and humidity control. Temperature and humidity control accuracy
3. Cleanliness requirements 4. Illuminance requirements
5. The volume of heat and moisture equipment range 6. Air-conditioning the way back to the wind
7. Air balance measures 8. The need for the introduction of a new wind
9. The need for the exhaust system 10. Insulation measures
11. The allocation of power facilities and 12. Static, vibration and noise
13. Equipment 14 between space and air-conditioning. And changing access arrangements for the buffer zone
15. Sufficient maintenance space 16. Interior clear height and floor load
17. Pollution, pollution and prevention 18. The cost of installation and operation of measuring the
19. Aesthetic requirements 20. Installation cost / project control
21. Operating cost of 22. Maintainability & flexibility factor
 
 
 
Third, the operational features of constant temperature and humidity laboratory
• constant temperature and humidity laboratory, independent of direct evaporative air-conditioning system of constant temperature and humidity, with a simple, easy adjustment, easy operation and management, energy-saving advantages. In engineering design, based on the accuracy of laboratory temperature and humidity requirements of the system a reasonable choice, as far as possible, a detailed calculation of the room and select the load of constant temperature and humidity to match unit.
• In order to meet the requirements of the accuracy of the indoor temperature and humidity, constant temperature and humidity of the air changes an air-conditioned room, and the light of experience, ± 2 ℃ constant temperature room, ventilation frequency of about 10 ~ 15 times / h; ± 1 ℃ constant temperature room, ventilation frequency of about 15 ~ 20 times / h; ± 0.5 ℃ constant temperature room, ventilation frequency of about> 20 times / h; ± 0.2 ℃ constant temperature room, ventilation frequency of about> 30 times / h;
• is the impact of organizational design airflow room temperature accuracy of one of the main factors in the design of high-precision temperature and humidity of indoor air organizations should consider the principles: a reasonable flow of air distribution, air flow and give full play to the role of cooling or heating; the establishment of a stable uniform temperature field in order to ensure the flow to reach the work area, the average temperature and temperature difference of the work area does not exceed the value of temperature fluctuation permitted; air to reach the work area, the flow rate of 0.25m / s or so. ± 2 ℃ and high-precision ± 1 ℃ constant temperature and humidity laboratory, using the whole orifice plate and local air, the lower uniform wind back, better.
• the construction of laboratories in the constant temperature and humidity, the heat sealing is very critical; heat sealed with a good laboratory to save energy and improve the accuracy of temperature and humidity, reduce operating costs and so on.
  
 
Home | About Us | Project Performance | Project Performance | News | Recrui Tment | Bulletin Board | Contact Us